#Please install the box so that rain should not set in directly to it. Please give the waterproof processing when it is assumed that the water which adheres to the sheet splashes to the connector of motor/brake sensor code.
#The production of the shutter is in 100mm.
#Please consult separately when the size of the product exceeds the range of the standard. Please agree that the production of the shutter is not possible.
#Please read the operation manual carefully and use the shutter correctly.
#Please raise the sheet of the shutter to the upper limit position when not using it. The sheet might come off from the frames because of the gust etc. , and that might cause the injury.
| For single phase |
KV10
[for indoor only] |
KV20 |
KV25 |
KV30/WV30 |
KV40/WV40 |
KV50 |
| size |
W |
800~2500 |
800~3200 |
3000~4200 |
(KV)4300~5300
(WV)800~3500 |
(KV)5400~7000
(WV)3600~5000 |
7100~10000 |
| H |
1000~3800 |
1000~5000 |
standard type:
W=5400-6100
→up to 5100H
W=6200-7000
→up to 4200H
special order type:
up to 5900H |
2000~6000 |
| external size |
W+156 |
W+236 |
W+286 |
| motor |
power supply |
single phase AC200V~230V±10% |
| speed |
opening:1.6m/s
closing:0.7m/s |
KV20/25/30 opening:1.0m/s closing:0.7m/s
WV30 opening:0.7m/s closing:0.55m/s |
KV40/50 opening:0.5m/s
closing:0.5m/s
WV40 opening:0.4m/s closing:0.4m/s |
| reduction ratio |
1/10 |
1/23 |
1/50
(in case of WV30, 1/74) |
1/74 |
| reduction method |
YUSEI HASUBA gear reduction system |
| insulation |
B class |
| photocell sensor |
equipment |
1 set each on front and rear of the frames |
| installation |
both in the frames (4 additional installation holes) |
| core material of sheet |
middle pipe |
φ15.9×t1.2 |
φ27.2×t1.2 |
φ38.1×t1.2 (WV30 φ27.2×t1.2) |
φ48.6×t1.8 |
| high tension pipe |
| auxiliary pipe |
φ27.2×t1.2 |
φ38.1×t1.2 |
φ48.6×t1.8 |
| high tension pipe |
bottom pipe
|
φ26×t3.0 |
φ38×t3.5 |
(KV)φ48×t4.0 / (WV)φ38×t3.5 |
| resin pipe |
| box |
steel |
hard PVC |
aluminium |
| frequency in use |
up to 100 times / hour |
up to 60 times / hour |
up to 50 times / hour |
| condition of use |
temperature from -10℃ to 40℃ except freeze humidity RH85% or less
condition: under no condensation, no freeze, no fine particles, no poisonous gas, and no causticity atmosphere. |
| notice for power supply |
Please consult the electrical work trader about the wiring to the power supply. |
*For the frames of KV10, we prepares a united specification and a divided specification.
Please specify it when you order.
| For 3-phase |
SV25 |
SV30 |
SV40 |
| size |
W |
3000~3700 |
3400~5300 |
5400~6500 |
| H |
W3000~3300→up to 5000H
W3400~3700→up to 4200H |
1000~5000 |
1000~5900 |
| external size |
W+236 |
W+286 |
| motor |
power supply |
3-phase AC200V ±10% |
| speed |
opening:1.0m/s
closing:0.7m/s |
opening:0.5m/s
closing:0.5m/s |
| reduction ratio |
1/25 |
1/43 |
| reduction method |
Cyclo reduction system |
| insulation |
B class |
| photocell sensor |
equipment |
1 set each on front and rear of the frames |
| installation |
both in the frames (4 additional installation holes) |
| core material of sheet |
middle pipe |
φ38.1×t1.2 |
| high tension pipe |
| auxiliary pipe |
φ38.1×t1.2 |
| high tension pipe |
bottom pipe
|
φ38×t3.5 |
φ48×t4.0 |
| resin pipe |
| box |
steel |
hard PVC |
aluminium |
| frequency in use |
up to 100 times / hour |
up to 60 times / hour |
| condition of use |
temperature from -10℃ to 40℃ except freeze humidity RH85% or less
condition: under no condensation, no freeze, no fine particles, no poisonous gas, and no causticity atmosphere. |
| notice for power supply |
Please consult the electrical work trader about the wiring to the power supply. |